The room that was never a room

A converted garage is a different building attached to your house

Uninsulated slab, a wall that was a door, almost no attic above it, and a heating system that was sized years before the space existed. That is why it is never comfortable, and why the usual answer makes the rest of the house worse.

Why these rooms behave badly

Four things are true of nearly every one of them

The slab is uninsulated and often below the rest of the floor. A garage slab was poured to take a car, not to sit under a bed. It is usually thinner, usually has no perimeter insulation and frequently no vapour barrier, which is why these rooms are cold in January and clammy in August.

The wall where the door was is the weakest wall in the house. Filling a garage opening is straightforward building work and it is very often done with less insulation than the original walls, no proper air sealing at the header, and a window sized for light rather than for heat.

There is almost no attic above it. Garage roofs are usually shallower, with less depth for insulation and less ventilation, so the ceiling of a converted garage runs hotter than any other ceiling in the building.

And the heating system does not know the room exists. It was sized for the house as built. Whatever is being asked of it now, it was never designed to do.

Work it through

What the space is, and how you were thinking of heating and cooling it

Nothing is sent anywhere and nothing is recorded. This is what we would ask you on the telephone.

Extending the existing system is what almost everybody asks for, and it is the option that most often makes the rest of the house worse

The logic feels obvious: there is already a system, there are already ducts, so run a branch into the new room. The problem is that the system was sized for the house without that room, and a duct carries a fixed amount of air. A new register does not create airflow — it takes it from the rooms that were getting it before. People notice within a fortnight, usually in the bedroom furthest from the equipment.

Three measurements settle it, and all three can be taken in one visit: the calculated load of the new space on its own; the spare capacity of the existing equipment, which means what it is actually delivering rather than what is on its nameplate; and the static pressure and airflow the existing ductwork is running at. If the system is already at or over its rated static pressure — which, in this housing stock, it very often is — then there is no spare air to take and extending it is not an option at any price.

Where it genuinely does work: a small space, a system with real measured spare capacity, ductwork running comfortably within its limits, and a trunk close enough to branch from sensibly. It happens, and when it does it is the cheapest answer. We just will not assume it before measuring.

And one thing that is not ours to answer. In California a garage conversion is normally permitted building work, and permitted work carries requirements of its own about insulation, ventilation and how the space is heated. Ask your city or county building department, not us. We are a heating contractor and we will say so rather than guess on your behalf.

Our answer

Treat it as its own zone, because it behaves like its own building

A bedroom has a narrower comfort range than any other room in a house, it is occupied when the building is at its coldest and its hottest, and it needs to be quiet. A converted garage bedroom fails on all three for structural reasons rather than equipment ones.

Before any equipment: find out what is actually above and below you. If the ceiling has less than a usable depth of insulation, adding it is the cheapest degree of comfort you will ever buy. If the slab is bare, a floor covering with some insulation value changes how the room feels in January far more than its cost suggests.

Then the equipment: a single ductless head, sized by calculation for that room. It is quiet, it runs at low output for long periods, which is exactly what a bedroom wants, and it heats as well as cools. Mounted high on the wall furthest from the bed, not above it.

What we would avoid: a wall heater as the only heat source, because it heats the air near itself and nothing else, and an oversized head, because at night it will short-cycle and you will hear every start.

About a converted bedroom specifically

Ask about sound level at low output, in decibels, from the person quoting. It is published for every machine and it is the thing people complain about six months later.

If you were planning to extend the existing system

Read the note above before anything else on this page. In short: a new register does not create airflow, it takes it from somewhere else, and whether there is any to take is a measurement rather than an opinion. Ask for static pressure and airflow before you accept a price for a branch.

In every case

Four things to establish before anybody quotes

  • The calculated load of the space on its own

    Room by room, against what the space is actually made of now — not the floor area, and not the size of the room next door.

  • What the existing system is really delivering

    Measured output and static pressure, against the equipment’s rated limits. This is the number that decides whether extending is possible at all.

  • What the cheap building work would achieve

    Ceiling insulation, door insulation, shading and air sealing, honestly assessed — including what they will not fix. We do not do that work, which is rather the point of asking us.

  • Who owns the permit question

    Your building department and your builder. Not your heating contractor, and not a page on the internet. Ask them before the equipment is ordered rather than after.